ERbic | General information | Electrical and mechanical characteristics


ERbic Profibus

Interface Connector  D-Sub, 9-pin, male
D-Sub male or female (PU connection)  Class 2
D-Sub male reversed version  Class 3
Cable termination  2 x horizontal, 2 x vertical, MAX: 2 x axial
1 cable outlet can be sealed with blanking plate
Cable diameter 4.5 mm (0.177") - 8.0 mm (0.315")
Cross section of individual conductor  Screw terminal: solid max. 1.5 mm2; stranded max. 1.0 mm2
IDC terminal: solid ø 0.64 mm
Cage-clamp terminal: 0.08 - 0.5 mm2 (0.75 mm2)
Termination type Screw terminal, IDC terminal, cage-clamp terminal
Data transmission rate According to bus specification, 12 MBit/s
Temperature range -20 °C - +70 °C
Permissible humidity Max. 75 % at +25 °C, non-condensing
Protection class IP 40, MAX: IP 30
Housing material Thermoplast UL94V-1, MAX: ZnAl, galvanized
D-Sub screw #4/40 UNC, knurled with cross-head
UL approval UL E84703 *
CE marking ERbic connectors are passive components and do not need to be identified with the CE marking according to EU directives.

ERbic Profibus Ex i

Interface Connector  D-Sub, 9-pin, male
D-Sub male  Class 2
Cable termination  2 x horizontal
1 cable outlet can be sealed with blanking plate
Cable diameter 4.5 mm (0.177") - 8.0 mm (0.315")
Cross section of individual conductor  Screw terminal: solid max. 1.5 mm2; stranded max. 1.0 mm2
Termination type Screw terminal
Data transmission rate According to bus specification, 12 MBit/s
Temperature range -20 °C - +70 °C
Permissible humidity Max. 75 % at +25 °C, non-condensing
Protection class IP 40
Housing material Thermoplast UL94V-1
D-Sub screw #4/40 UNC, knurled with cross-head
UL approval UL E84703 *
CE marking ERbic connectors are passive components and do not need to be identified with the CE marking according to EU directives.

ERbic CAN Bus

Interface Connector  D-Sub, 9-pin, female
D-Sub female or male (PU connection)  Class 2
D-Sub female reversed version Class 3
Cable termination  2 x horizontal, 2 x vertical, MAX: 2 x axial
1 cable outlet can be sealed with blanking plate
Cable diameter 4.5 mm (0.177") - 8.0 mm (0.315")
Cross section of individual conductor  Screw terminal: 0.14 - 0.5 mm2; HLG 1.5 mm2
MAX: 0.14 - 1 mm2 (HLG)
Cage-clamp terminal: 0.08 - 0.5 mm2 (0.75 mm2) (HLG)
Termination type Screw terminal, cage-clamp terminal
Data transmission rate According to CAN specification, max. 1 MBit/s
Temperature range -20 °C - +70 °C
Permissible humidity Max. 75 % at +25 °C, non-condensing
Protection class IP 40, MAX: IP 30
Housing material Thermoplast UL94V-1, MAX: ZnAl, galvanized
D-Sub screw #4/40 UNC, knurled with cross-head
UL approval UL E84703 *
CE marking ERbic connectors are passive components and do not need to be identified with the CE marking according to EU directives.

ERbic SafetyBUS p

Interface Connector  D-Sub, 9-pin, female
D-Sub female Class 2
Cable termination  2 x horizontal
1 cable outlet can be sealed with blanking plate
Cable diameter 4.5 mm (0.177") - 8.0 mm (0.315")
Cross section of individual conductor  Max. 1.5 mm2
Termination type Screw terminal
Data transmission rate According to CAN specification, max. 1 MBit/s
Temperature range -20 °C - +70 °C
Permissible humidity Max. 75 % at +25 °C, non-condensing
Protection class IP 40,
Housing material Thermoplast UL94V-1, MAX: ZnAl, galvanized
D-Sub screw #4/40 UNC, knurled with cross-head
UL approval UL E84703 *
CE marking ERbic connectors are passive components and do not need to be identified with the CE marking according to EU directives.

* Due to continuous advancement, it is possible that the UL approval of a new version may not have been completed at the time of going to press.